|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
EE-SPX613 An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes Incorporates a Sensitivity Selector, Built-in Amplifier, and Operation Mode Selector Tie-wrap and rubber tube provided to prevent slippage Suitable for any 6- to 13-mm diameter transparent or semi-transparent pipe with a wall thickness of 1 mm Built-in amplifier saves space and wiring effort Compact size is ideal for the miniaturization of equipment Uses a talc-free cable that is ideal for equipment used for the manufacturing of semiconductors Ordering Information Appearance Detection method Through-beam (with groove) Output configuration Dark-ON or light ON (selectable) Part number EE-SPX613 EE-SPX613 EE-SPX613 Specifications RATINGS/CHARACTERISTICS Part Number Power supply voltage Current consumption Applicable pipe Sensing object Control output Average value Peak value EE-SPX613 12 to 24 VDC 10%, ripple (p-p): 5% max. 30 mA max. 80 mA max. Any 6- to 13-mm-diameter pipe with a wall thickness of 1 mm that is made of FEP or any other material as transparent as FEP. Liquids in pipes (High-viscosity liquids or liquids with floating materials may not be detected.) Voltage: Load current: Residual voltage: Indicator Connection method Enclosure rating Ambient illumination Light source Material Ambient temperature Ambient humidity y Vibration resistance Shock resistance Case Cover Operating Storage Operating Storage --10C to 55C (14F to 131F) --25C to 65C (-13F to 149F) (with no icing or condensation) 5% to 85% 5% to 95% (with no icing or condensation) Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 in X, Y, and Z directions 3 times and for 11 min each Destruction: 500 m/s2 in X, Y, and Z directions 3 times each 5 to 24 VDC 100 mA max. 0.8 V max. with a load current of 100 mA and 0.4 V max. with a load current of 40 mA Light indicator (red) (Lit with incident.) Pre-wired (cable length: 1 m) IEC IP50 3,000 x max. with incandescent light or sunlight on the receiver Infrared LED (with a wavelength of 940 nm) Polycarbonate y ATTACHMENTS Supporting belt Slip protection tube 2 2 Nomenclature PHYSICAL ATTRIBUTES Operation mode selector Sensitivity selector Light indicator (red) Cable EE-SPX613 EE-SPX613 Operation OUTPUT CIRCUIT Operating status of output transistor Output circuit Dark-ON Light indicator (Red) Light-ON 12 to 24 VDC (Brown) Main circuit Load 1 (Relay) (Black) Load 2 0V (Blue) * The RL is required if voltage output is required (i.e., transistor circuitry is connected). Timing chart Light (with no liquid) Dark (with liquid) Lit Light indicator (red) Not lit Output transistor Load 1 (Relay) Load 2 Start Reset Light (with no liquid) Dark (with liquid) Lit Light indicator (red) Not lit Output transistor Load 1 (Relay) Load 2 Start Reset OPERATION The EE-SPX613 detects the level of liquid by detecting the difference in refractive index between the air and liquid. 1. If there is no liquid in the pipe, the emitted beam will reach the receiver after it is refracted by the pipe. Pipe If the diameter of the pipe is close to 6 mm, some of the emitted light may reach the receiver because the angle of refraction is small. This may result in false readings. In such cases, set the sensitivity selector to Low and check that the EE-SPX613 reads correctly for pipes with and without liquid. If there are floating materials on the surface of the liquid, light reflected from the floating material may reach the receiver. In such cases, set the sensitivity selector to Low and check the operation of the EE-SPX613 for pipes with and without liquid. If transmission of the light is impaired by stains on the pipe or an emitter that has deteriorated with age, you may need to set the sensitivity to HIGH. Without liquid Emitter Receiver 2. If there is liquid in the pipe, the emitted beam will pass through the liquid and not reach the receiver. Pipe With liquid Emitter Receiver EE-SPX613 EE-SPX613 Dimensions Unit: mm EE-SPX613 Optical axis 14.4 16 (0.57) 8.5 (0.63) (0.33) Pedestal 26 (1.02) 13 (0.51) 1 (0.04) 1.6 12.4 9.2 (0.49) (0.36) Sensing slit (1.8 x 0.8) Optical axis 17.2 (0.68) 1.8 (0.07) Sensitivity selector 3.1 8.1 (0.32) Light indicator 6.6 dia. 3.5 (0.14) 4.9 (0.19) 4.5 (0.18) Round vinyl-insulated cable of 3.5 dia. (0.08 dia x 30), 3 cores Standard length: 1 m Operation mode selector Cable Precautions ! WARNING * Do not supply or impose on the EE-SPX613 any AC current or voltage exceeding the upper limit of the rated voltage range, or the EE-SPX613 may be damaged. * Do not short-circuit the load connected to the EE-SPX613, or the EE-SPX613 may be damaged. Brown Brown Sensor Black Blue Blue Load Sensor Load Black * Incorrect polarity resulting from wrong wiring or connections may result in injury to the user or damage to the equipment. Brown Load Black Sensor Blue EE-SPX613 EE-SPX613 ! Caution Mounting Always use supporting belts and slip protection tubes, which are provided with the EE-SPX613, when attaching the EE-SPX613 to an appropriate pipe, as shown in the following illustration. Make sure that the pipe is in the center of the sensor groove and not lifted from the pedestal. When tightening the supporting belts, make sure that the pipe will not be deformed. Slip protection tubes Supporting belts Power Supply Ground the FG and GND terminals if a standard switching regulator is used to supply power to the EE-SPX613, or the EE-SPX613 may malfunction . Operating Environment The EE-SPX613 is not watertight. Do not use the EE-SPX613 outdoors. Do not use the EE-SPX613 in places where water, oil, or chemicals may splash or be sprayed onto the unit. The exterior coverings of the EE-SPX613 are made of polycarbonate. Keep the coverings away from any alkaline, aromatic hydrocarbon, or aliphatic chloride hydrocarbon solvent, all of which will damage the coverings. Pipe Pedestal Sensor Others * The EE-SPX613 requires 10 ms to be in stable operation after power is supplied. If two power supplies are used for the EE-SPX613 and load respectively, be sure to supply power to the EE-SPX613 before supplying power to the load. If there is a high-tension line near the cable, wire the cable through an independent metal conduit to protect the EE-SPX613 from damage or malfunction. Do not attach the EE-SPX613 to improper pipes, such as non-transparent pipes, or the EE-SPX613 may not operate properly. * * Do not impose any excessive force on the cable. Do not pull the cable with a force exceeding 30 N. Use an extension cable with conductors having a total crosssectional area of 0.15 mm2 (i.e., AWG26) and a total cable length of 5 m maximum. Do not impose a force exceeding 5 N on the operation mode selector or sensitivity selector. * * * NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON Cat. No. EO5DAX4 1/99 Specifications subject to change without notice. 416-286-6465 Printed in U.S.A. |
Price & Availability of EE-SPX613 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |