EE-SPX613
An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes Incorporates a Sensitivity Selector,
Built-in Amplifier, and Operation Mode Selector
Tie-wrap and rubber tube provided to
prevent slippage
Suitable for any 6- to 13-mm diameter
transparent or semi-transparent pipe with a wall thickness of 1 mm
Built-in amplifier saves space and wiring
effort
Compact size is ideal for the
miniaturization of equipment
Uses a talc-free cable that is ideal for
equipment used for the manufacturing of semiconductors
Ordering Information
Appearance Detection method Through-beam (with groove) Output configuration Dark-ON or light ON (selectable) Part number EE-SPX613
EE-SPX613
EE-SPX613
Specifications
RATINGS/CHARACTERISTICS
Part Number Power supply voltage Current consumption Applicable pipe Sensing object Control output Average value Peak value EE-SPX613 12 to 24 VDC 10%, ripple (p-p): 5% max. 30 mA max. 80 mA max. Any 6- to 13-mm-diameter pipe with a wall thickness of 1 mm that is made of FEP or any other material as transparent as FEP. Liquids in pipes (High-viscosity liquids or liquids with floating materials may not be detected.) Voltage: Load current: Residual voltage: Indicator Connection method Enclosure rating Ambient illumination Light source Material Ambient temperature Ambient humidity y Vibration resistance Shock resistance Case Cover Operating Storage Operating Storage --10C to 55C (14F to 131F) --25C to 65C (-13F to 149F) (with no icing or condensation) 5% to 85% 5% to 95% (with no icing or condensation) Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 in X, Y, and Z directions 3 times and for 11 min each Destruction: 500 m/s2 in X, Y, and Z directions 3 times each 5 to 24 VDC 100 mA max. 0.8 V max. with a load current of 100 mA and 0.4 V max. with a load current of 40 mA
Light indicator (red) (Lit with incident.) Pre-wired (cable length: 1 m) IEC IP50 3,000 x max. with incandescent light or sunlight on the receiver Infrared LED (with a wavelength of 940 nm) Polycarbonate y
ATTACHMENTS
Supporting belt Slip protection tube 2 2
Nomenclature
PHYSICAL ATTRIBUTES
Operation mode selector Sensitivity selector Light indicator (red)
Cable
EE-SPX613
EE-SPX613
Operation
OUTPUT CIRCUIT
Operating status of output transistor Output circuit Dark-ON
Light indicator (Red)
Light-ON
12 to 24 VDC
(Brown)
Main circuit
Load 1 (Relay)
(Black)
Load 2 0V
(Blue)
* The RL is required if voltage output is required (i.e., transistor circuitry is connected). Timing chart
Light (with no liquid) Dark (with liquid) Lit Light indicator (red) Not lit Output transistor Load 1 (Relay) Load 2 Start Reset Light (with no liquid) Dark (with liquid) Lit Light indicator (red) Not lit Output transistor Load 1 (Relay) Load 2 Start Reset
OPERATION
The EE-SPX613 detects the level of liquid by detecting the difference in refractive index between the air and liquid. 1. If there is no liquid in the pipe, the emitted beam will reach the receiver after it is refracted by the pipe.
Pipe
If the diameter of the pipe is close to 6 mm, some of the emitted light may reach the receiver because the angle of refraction is small. This may result in false readings. In such cases, set the sensitivity selector to Low and check that the EE-SPX613 reads correctly for pipes with and without liquid. If there are floating materials on the surface of the liquid, light reflected from the floating material may reach the receiver. In such cases, set the sensitivity selector to Low and check the operation of the EE-SPX613 for pipes with and without liquid. If transmission of the light is impaired by stains on the pipe or an emitter that has deteriorated with age, you may need to set the sensitivity to HIGH.
Without liquid
Emitter
Receiver
2. If there is liquid in the pipe, the emitted beam will pass through the liquid and not reach the receiver.
Pipe
With liquid
Emitter
Receiver
EE-SPX613
EE-SPX613
Dimensions
Unit: mm
EE-SPX613
Optical axis 14.4 16 (0.57) 8.5 (0.63) (0.33)
Pedestal 26 (1.02) 13 (0.51) 1 (0.04) 1.6 12.4 9.2 (0.49) (0.36) Sensing slit (1.8 x 0.8) Optical axis
17.2 (0.68)
1.8 (0.07) Sensitivity selector 3.1 8.1 (0.32) Light indicator
6.6 dia.
3.5 (0.14)
4.9 (0.19) 4.5 (0.18)
Round vinyl-insulated cable of 3.5 dia. (0.08 dia x 30), 3 cores Standard length: 1 m
Operation mode selector
Cable
Precautions
! WARNING
* Do not supply or impose on the EE-SPX613 any AC current or voltage exceeding the upper limit of the rated voltage range, or the EE-SPX613 may be damaged. * Do not short-circuit the load connected to the EE-SPX613, or the EE-SPX613 may be damaged.
Brown Brown Sensor Black Blue Blue Load Sensor
Load Black
*
Incorrect polarity resulting from wrong wiring or connections may result in injury to the user or damage to the equipment.
Brown
Load Black
Sensor Blue
EE-SPX613
EE-SPX613
! Caution
Mounting
Always use supporting belts and slip protection tubes, which are provided with the EE-SPX613, when attaching the EE-SPX613 to an appropriate pipe, as shown in the following illustration. Make sure that the pipe is in the center of the sensor groove and not lifted from the pedestal. When tightening the supporting belts, make sure that the pipe will not be deformed.
Slip protection tubes Supporting belts
Power Supply
Ground the FG and GND terminals if a standard switching regulator is used to supply power to the EE-SPX613, or the EE-SPX613 may malfunction .
Operating Environment
The EE-SPX613 is not watertight. Do not use the EE-SPX613 outdoors. Do not use the EE-SPX613 in places where water, oil, or chemicals may splash or be sprayed onto the unit. The exterior coverings of the EE-SPX613 are made of polycarbonate. Keep the coverings away from any alkaline, aromatic hydrocarbon, or aliphatic chloride hydrocarbon solvent, all of which will damage the coverings.
Pipe
Pedestal Sensor
Others
* The EE-SPX613 requires 10 ms to be in stable operation after power is supplied. If two power supplies are used for the EE-SPX613 and load respectively, be sure to supply power to the EE-SPX613 before supplying power to the load. If there is a high-tension line near the cable, wire the cable through an independent metal conduit to protect the EE-SPX613 from damage or malfunction. Do not attach the EE-SPX613 to improper pipes, such as non-transparent pipes, or the EE-SPX613 may not operate properly. * * Do not impose any excessive force on the cable. Do not pull the cable with a force exceeding 30 N. Use an extension cable with conductors having a total crosssectional area of 0.15 mm2 (i.e., AWG26) and a total cable length of 5 m maximum. Do not impose a force exceeding 5 N on the operation mode selector or sensitivity selector.
*
*
*
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC. OMRON CANADA, Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema INC.
One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8
1-800-55-OMRON
Cat. No. EO5DAX4 1/99 Specifications subject to change without notice.
416-286-6465
Printed in U.S.A.


▲Up To Search▲   

 
Price & Availability of EE-SPX613

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X